Steam and air meter ELKORA S-23

The measuring device is intended for accurate commercial and technological accounting of the consumed and developed steam heat energy in heat supply systems, as well as for measuring the flow and quantity of compressed air.

Features and benefits

  • Wide flow measurement range.
  • There are no moving parts for a long service life.
  • Constant relative measurement error over the entire range.
  • 1 flow sensor, 1 pressure sensor and 1-2 (depending on the order) temperature sensors can be connected to one electronic unit.
  • Three-year warranty with post-warranty service.

Technical parameters

  • The heat meter complies with EN 1434 accuracy class 2.
  • The flow measurement range is given in the table.
  • Temperature measurement range 0°C – 300°C.
  • Power supply: 100V – 240V, 50Hz – 60Hz.
  • Output signals: current, frequency and pulse, interface RS 232, interface Centronics.
  • Connection: flange DN 32 – DN 300.

Data storage options

ELKORA meters allow the following values ​​of current and integral parameters to be stored in the memory:

+Hourly average and daily average (archive 768 hours and 64 days);

+Amount per day and amount per month (archive 64 days and 32 months);

+Shutdown time per day and month (archive 64 days and 32 months).

DNQ min m3/hQ max m3/h
3215250
4020400
5030600
65501 000
80701 400
1001002 000
1251603 200
1502505 000
2004509 000
25070014 000
3001 00020 000
Dimenssions
Installation and connection
The spatial arrangement of the flow sensor can be both horizontal and vertical.
The gaskets must not protrude into the measuring part.